active rear door heat exchanger
door heat exchanger
rdhx

Rear Door Heat Exchanger (RDHx) – High-Density Data Center Cooling

The rear door heat exchanger is a highly efficient data center cooling solution designed to manage heat directly at the rack level across Dubai, UAE, and the Middle East. It enables targeted cooling for high-density IT environments without increasing room-level cooling demand.

This RDHx solution, also known as an active rear door heat exchanger or cooldoor, removes heat from server exhaust air before it enters the data center space. The door heat exchanger supports improved thermal efficiency and optimized airflow management.

Suitable for modern and scalable data center designs, RDHx cooling helps reduce energy consumption while maintaining stable operating temperatures in demanding Middle East climate conditions.

Targeted Rack-Level Cooling

  • Removes heat directly from server exhaust air
  • Supports high-density rack deployments
  • Reduces thermal load on room cooling systems
  • Improves airflow efficiency within the data center
  • Enhances overall cooling performance

Optimized for Energy Efficiency

  • Active cooling design: Supports high-efficiency heat exchange
  • Rack-level deployment: Enables localized thermal management
  • Space-saving solution: No additional floor space required
  • Scalable integration: Suitable for existing and new data centers
  • Energy-efficient operation: Helps reduce cooling power usage
  • Operational reliability: Supports continuous data center operation

Types

30kW Rear Door Heat Exchanger

The 30kW rear door heat exchanger by Dutco Tennant LLC is designed for medium-density racks, providing efficient RDHx cooling while maintaining stable airflow and temperature control in UAE data center environments.

It supports balanced performance and energy efficiency.

  • Ideal for mid-density server racks
  • Efficient heat removal capacity
  • Easy rack-level integration

50kW Rear Door Heat Exchanger

The 50kW rear door heat exchanger supports high-density racks by removing large heat loads directly at the source, making it suitable for advanced data center deployments across the Middle East.

It enables higher rack power densities.

  • Supports high-power racks
  • Enhanced heat exchange performance
  • Optimized for dense environments

Active Rear Door Heat Exchanger

An active rear door heat exchanger uses integrated fans to enhance airflow and heat removal, delivering consistent cooling performance for demanding rack-level applications.

It supports stable thermal conditions.

  • Active airflow assistance
  • Improved heat transfer efficiency
  • Suitable for high-density workloads

CoolDoor RDHx System

The CoolDoor system integrates seamlessly with server racks to provide efficient rear door heat exchanger functionality without major infrastructure changes.

It supports flexible deployment.

  • Rack-compatible design
  • Minimal infrastructure modification
  • Efficient rack-level cooling

Standout Features & Benefits

Direct Heat Removal

  • Captures and removes heat at the rack exhaust
  • Prevents hot air recirculation
  • Improves cooling efficiency

Reduced Energy Consumption

  • Lowers load on traditional cooling systems
  • Supports energy-efficient data center operations
  • Helps reduce operational costs

Scalable Cooling Design

  • Supports increasing rack power densities
  • Integrates with existing cooling strategies
  • Enables future-ready data center expansion

Application Areas

Enterprise Data Centers

  • Supports high-density server racks
  • Enhances rack-level cooling efficiency
  • Improves thermal stability

Colocation Facilities

  • Enables higher rack power density offerings
  • Improves cooling performance per rack
  • Supports scalable deployments

High-Performance Computing (HPC)

  • Suitable for compute-intensive environments
  • Maintains stable rack temperatures
  • Supports continuous high-load operations