Download Brochure
  • Dutco Tennant LLC, PO Box 233, Dubai, U.A.E.
membrane fouling prevention chemicals in UAE
RO membrane fouling removal in Dubai
best biofouling removal chemicals

Genesys Membrane Fouling Prevention and Removal Chemicals for RO Systems

Scale, biofilm, organic deposits, iron, and colloidal silica accumulating on RO and NF membrane surfaces reduce permeate output, raise operating pressure, and accelerate membrane replacement cycles. Genesys membrane fouling chemicals address both prevention and removal, targeting every foulant type across seawater, brackish water, and process water RO systems without damaging membrane polymer integrity.

Optimise water treatment with genesys membrane fouling chemicals. Effective for preventing and removing fouling in RO and industrial water systems. The range covers antiscalants, alkaline and acid cleaners, biocidal cleaners, flocculants, and UF-specific formulations under the Genesys and Genesol product lines for systems of every scale.

Dutco Tennant LLC supplies membrane fouling prevention chemicals from Genesys International across the UAE and GCC, serving contractors, consultants, and water treatment project developers.

Proactive Fouling Control and Targeted Cleaning

  • Antiscalant dosing ahead of membranes prevents scaling from calcium carbonate, sulphate, silica, and metal ions before deposition occurs.
  • Membrane Master software analyses feed water chemistry, enabling accurate antiscalant selection and dose optimisation during system design and operation.
  • Flocculant pre-treatment reduces suspended solids and SDI, improving upstream water quality without introducing fouling-causing residues.
  • Correct chemical selection minimises cleaning frequency, extending membrane life and reducing downtime and operational cost.
  • Membrane autopsy services identify actual foulants, ensuring precise chemical selection for persistent or complex fouling conditions.

Core Technical Capabilities

  • Antiscalant Coverage: Effective against carbonate, sulphate, silica, iron, manganese, and complex scale across RO and NF systems.
  • Cleaner pH Range: Alkaline cleaners remove organic and biological fouling; acid cleaners dissolve inorganic scale within membrane tolerance limits.
  • Biocide Application: On-line and off-line treatment options available, with safe neutralisation before system restart.
  • UF Compatibility: Dedicated formulations address iron, biofouling, and scaling in UF systems supporting RO pre-treatment.
  • Compliance: Certified formulations meet potable water and environmental standards with consistent manufacturing quality.

Types

Antiscalant and Antifoulant

Membrane fouling prevention chemicals in the Genesys antiscalant range dose continuously into the RO feed stream, inhibiting scale precipitation and sequestering trivalent metal cations before they deposit on the membrane.

  • Genesys LF is a general-purpose phosphonate antiscalant for seawater and brackish water RO and NF systems, effective against a broad range of inorganic scaling species including iron and manganese
  • Genesys SW and Genesys LS are phosphorus-free seawater antiscalants with Drinking Water Inspectorate registration, covering large municipal and potable desalination plant applications
  • Genesys BS targets barium sulphate and high calcium carbonate scaling in process and industrial water RO systems where standard antiscalants do not provide adequate inhibition

Alkaline Membrane Cleaner

An alkaline Genesol cleaner uses blended chelating agents and non-ionic surfactants at high pH to remove organic foulants, colloidal deposits, and biological matter from RO and NF membranes.

  • Genesol 34 is a readily biodegradable alkaline general-purpose cleaner that removes both organic and inorganic deposits, effective as a standalone cleaner or in combination with other Genesol products
  • Genesol 704 targets aluminosilicate clay and aluminium-based foulants that resist conventional alkaline cleaners, covering systems using aluminium-based coagulants in pre-treatment
  • Genesol 80 specifically addresses glycocalyx biofilm layers secreted by bacteria under stress, removing extracellular polysaccharide material that standard alkaline cleaners do not fully penetrate

Acid Membrane Cleaner

An acid Genesol cleaner uses self-adjusting low-pH formulations to dissolve inorganic scale, iron oxides, and metal hydroxide deposits from RO, NF, and UF membrane surfaces.

  • Genesol 38 is an inorganic scale cleaner and iron deposit remover approved for drinking water applications, with self-adjusting pH maintaining optimum iron salt solubility throughout the cleaning cycle
  • Genesol 37 combines inorganic scale and iron oxide removal with organic deposit cleaning capability, covering severely fouled systems with mixed inorganic and organic foulant layers
  • Genesol UF Fe is a low-pH cleaner formulated specifically to remove iron and manganese fouling from UF membranes on SWRO pre-treatment systems where iron loading from feed water is high

Biocidal Cleaner

Biofouling removal chemicals in the Genesol biocide range eliminate active bacterial colonies and biofilm from RO and NF membrane surfaces and associated pre-treatment pipework, pumps, and tanks.

  • Genesol 30 is a fast-acting, broad-spectrum RO membrane fouling removal biocide used on-line and off-line to eliminate microbiological fouling, deactivated safely using sodium bisulphite after treatment
  • Genesol 32 operates as both a membrane cleaner and a pre-treatment system biocide, controlling biofouling in storage tanks, dosing pipework, and pre-filter housings alongside membrane treatment
  • Non-oxidising formulations throughout the biocide range are membrane-compatible, avoiding the irreversible oxidative damage that chlorine-based biocides cause to polyamide composite membrane elements

Flocculant and Ancillary Products

Genefloc and ancillary Genesys products support pre-treatment performance, reducing the foulant load reaching the membrane and improving the effectiveness of antiscalant and cleaner dosing programmes.

  • Genefloc GPF is a general-purpose flocculant for surface, well, and process waters with medium to high SDI values, reducing colloidal and suspended solids loading without introducing membrane-fouling coagulant residues
  • Neutral pH Genesol 61 cleaner removes organic and inorganic foulants from RO and NF membranes at mid-range pH, covering systems where health, safety, or effluent disposal restrictions prevent high and low pH chemical use
  • Genairclean delivers a revolutionary air-assisted membrane cleaning approach, using controlled air scouring combined with chemical contact to dislodge compacted deposits from lead elements without increased CIP chemical concentration

Standout Features & Benefits

Proven Foulant-Specific Formulations

  • Each Genesys and Genesol product targets a defined foulant category — scale, organics, biofilm, iron, or colloidal particles — preventing the ineffective cleaning that results from using a non-matched general-purpose product
  • Membrane autopsy analysis before selecting a cleaning protocol ensures foulant deposits are correctly identified, avoiding repeated cleaning cycles that fail to restore normalised performance
  • Staged cleaning protocols combining alkaline first and acid second address mixed fouling conditions in a single CIP event without foulant cross-precipitation between cleaning stages

Membrane-Safe, Biodegradable Chemistry

  • All antiscalant and cleaner formulations are tested against polyamide, cellulose acetate, and polysulfone membrane materials, confirming no measurable change in salt rejection or membrane morphology after repeated use
  • Readily biodegradable classifications across Genesol 34 and biocidal cleaners support compliant waste stream disposal through standard wastewater treatment without specialist effluent neutralisation
  • Biofouling removal chemicals in the non-oxidising Genesol biocide range deactivate to harmless by-products using sodium bisulphite, meeting potable water safety requirements after off-line membrane treatment

Reduced Operating and Capital Cost

  • Correct antiscalant selection and dosing extends the interval between CIP cleaning cycles, reducing chemical consumption, labour, and production downtime across municipal and industrial RO plants
  • Genesys membrane fouling prevention maintained through proactive antiscalant dosing delays membrane element replacement, lowering capital expenditure on large multi-vessel RO systems significantly over the plant design life
  • Membrane Master scaling prediction software eliminates trial-and-error antiscalant selection, reducing the risk of under-dosing that causes irreversible scaling and over-dosing that increases chemical cost unnecessarily

Broad System and Feed Water Compatibility

  • The antiscalant range covers seawater, brackish water, wastewater reuse, and high-hardness process water feed sources within the same Genesys product family without requiring non-standard formulations
  • RO membrane fouling removal cleaners in the Genesol range are compatible with all standard CIP system configurations, PVC and stainless steel pipework, and fibreglass and steel tank construction without accelerating corrosion
  • UF-specific cleaner formulations extend the same foulant-matched chemistry approach to hollow-fibre UF pre-treatment systems, providing a single chemical supplier for the full membrane train

Application Area

Municipal Desalination and Water Treatment

  • Genesys SW, LS, and MP antiscalants prevent inorganic scale on large municipal seawater and brackish water RO plants producing potable water under Drinking Water Inspectorate and NSF/ANSI 60 certified chemistry
  • Genesol biocidal cleaners control biofouling on municipal RO systems treating surface water and reclaimed water sources with high seasonal biological loading during warm weather periods
  • Membrane fouling prevention chemicals on multi-stage municipal RO systems are applied at the design-optimised dose rate using Membrane Master modelling, supporting lowest possible chemical consumption per cubic metre of product water

Industrial Process Water and Cooling

  • RO membrane fouling removal using Genesol acid cleaners addresses the high inorganic scaling tendency of cooling tower makeup water and process water RO concentrate streams in manufacturing and petrochemical facilities
  • Flocculant pre-treatment with Genefloc GPF on high-SDI process water sources reduces colloidal fouling on lead elements, protecting antiscalant performance and extending cleaning intervals in industrial RO systems
  • Neutral pH Genesol 61 cleaner suits industrial process water RO systems on sites where effluent pH limits or health and safety policies restrict the use of high and low pH cleaning chemicals during CIP operations

Food, Beverage, and Pharmaceutical

  • NSF/ANSI 60 certified antiscalants and DWI-registered formulations confirm suitability for use on RO systems producing water in direct or indirect contact with food, beverage, and pharmaceutical products
  • Enzymatic and alkaline Genesol cleaners remove protein, fat, and starch-based organic foulants from RO and NF membranes on dairy, juice concentration, brewing, and pharmaceutical purified water systems
  • Biofouling removal chemicals using Genesol 30 off-line biocidal treatment eliminates bacterial contamination on food and beverage RO systems during scheduled production shutdowns without membrane damage

Commercial Buildings and Hotels

  • Antiscalants on commercial building RO systems serving hotels, hospitals, and mixed-use developments prevent hard water scale on membranes in regions with high calcium carbonate and silica feed water concentrations
  • Genesol acid cleaners restore permeate flow on building water purification systems where scale accumulation has reduced product water output below the demand required by the building's daily consumption profile
  • Compact liquid concentrate formats minimise storage volume requirements in commercial building plant rooms with limited chemical storage space adjacent to the RO system installation