From supplying water to residential buildings to operating heavy machinery in manufacturing plants, industrial motors play an important role in keeping essential services running. However, the moment a large motor starts, it can place considerable pressure on the electrical supply and the equipment it operates.
For instance, when a large industrial pump starts suddenly, it draws a high amount of electrical current and can cause a rapid change in water pressure. Similarly, sudden acceleration in heavy machinery can place additional strain on moving components.
Soft starters for motors help overcome these challenges by allowing motors to accelerate gradually. They are particularly useful in facilities where reducing starting current and maintaining a stable electrical supply are important operational requirements.
As part of its Electrical Network portfolio, Dutco Tennant LLC supplies medium voltage soft starting solutions for industrial and infrastructure projects across the UAE and GCC.
What Happens When an Industrial Motor Starts Suddenly?
An industrial motor generally requires more electrical current during starting than it does during normal operation. This initial demand is known as inrush current.
When a motor receives full voltage immediately, it can create two main challenges:
| Type of stress | What happens | Components affected |
|---|---|---|
| Electrical stress | A sudden increase in current can cause temporary voltage drops and additional heating. | Transformers, cables, motor windings and electrical panels |
| Mechanical stress | Rapid acceleration can create sudden force on connected machinery. | Bearings, shafts, couplings and pumps |
| Hydraulic stress | A sudden change in pump speed can affect water flow and pressure. | Pipelines, valves and pumping equipment |
Although these effects vary according to the motor and application, repeated uncontrolled starting can contribute to equipment deterioration and operational disruptions.
This is where soft starting technology becomes useful.
Medium Voltage Soft Starter – A Solution for Controlled Motor Starting
A Soft Starter is an electrical device that controls the voltage supplied to a motor during starting, allowing it to accelerate gradually instead of starting suddenly at full voltage.
A simple way to understand this is to compare it with driving a car. Pressing the accelerator suddenly creates a rapid movement, whereas applying it gradually allows the car to gain speed more smoothly.
A soft starter applies a similar principle to industrial motors.
A medium voltage soft starter is specifically designed for motors operating on medium voltage electrical supplies. These motors are commonly used in large pumping stations, industrial plants and infrastructure facilities.
How Does a Medium Voltage Soft Starter Work?
The FCMAplus soft starting system uses air-core reactor technology. A reactor is an electrical component that helps limit alternating current.
During motor starting, the reactor reduces the voltage available to the motor. As the motor gains speed, the voltage available to it increases.
Once the motor reaches the required operating conditions, a bypass device allows it to operate from the normal electrical supply.
This process helps manage starting current while reducing sudden mechanical loading.
How Soft Starters Reduce Electrical and Mechanical Stress
Reducing the Sudden Demand for Electricity
When a large motor starts directly, it can temporarily draw several times its normal operating current.
A reduced-voltage soft starting system helps limit this initial demand. This reduces the short-term electrical loading placed on transformers, cables and other power distribution components.
For facilities operating several industrial motors, managing starting current can be particularly important.
Minimising Voltage Drops
Have you ever noticed lights briefly dimming when a powerful electrical appliance is switched on?
A similar situation can occur within an industrial electrical network when a large motor starts.
Medium voltage soft starters help minimise these temporary voltage drops by limiting the initial current drawn by the motor. This can help reduce disturbances to other equipment connected to the same electrical supply.
Reducing Wear on Mechanical Components
Industrial motors are connected to machinery through components such as shafts, bearings and couplings.
When a motor accelerates suddenly, these components can experience abrupt mechanical loading. Gradual acceleration helps reduce this mechanical shock, potentially contributing to longer component life and lower maintenance requirements.
Supporting Smoother Water Pump Operation
When a large water pump starts suddenly, the rapid change in water flow can create pressure fluctuations within the pipeline.
Soft starters for pumps help the motor accelerate gradually, allowing water flow to increase in a more controlled manner.
However, separate surge protection may still be required to address pressure changes caused by sudden pump shutdowns, power failures or valve operations.
Types of Soft Starters for Industrial Motors
Different industrial applications require different starting arrangements. A water pump may have relatively simple starting requirements, while a heavy compressor may need a higher-capacity starting system.
Standard Medium Voltage Soft Starter
A standard soft starter is designed for general industrial applications where the motor needs to accelerate smoothly without drawing excessive starting current.
It is suitable for compatible pumps, conveyors and other fixed-speed equipment.
Heavy-Duty Soft Starter
Heavy-duty soft starters are designed for more demanding applications involving large machinery, longer starting periods or frequent starting cycles.
These configurations may be considered for industrial compressors, heavy-duty fans and machinery requiring additional starting capacity.
Integrated Soft Starter with Bypass
This configuration includes a bypass arrangement that allows the motor to operate directly from the electrical supply after completing the starting process.
The bypass helps avoid unnecessary power losses associated with keeping the starting components in the motor's normal operating circuit.
| Type | Main purpose | Typical applications |
|---|---|---|
| Standard soft starter | Controlled motor starting | Pumps and conveyors |
| Heavy-duty soft starter | Managing demanding starting conditions | Large compressors and industrial fans |
| Soft starter with bypass | Controlled starting followed by normal supply operation | Fixed-speed industrial machinery |
These configurations are not necessarily mutually exclusive. A heavy-duty soft starter may also incorporate a bypass arrangement.
Common Applications of Medium Voltage Soft Starters
Soft starters are used across industries where large motors need to start reliably without placing unnecessary pressure on electrical networks and mechanical equipment.
Water and Wastewater Treatment Plants
Large pumps and aeration equipment are essential for transporting and treating water. Soft starters help manage the initial electrical demand while supporting controlled pump acceleration.
Desalination Facilities
Desalination plants rely on powerful pumps to transport seawater and treated water through different processes. Soft starters can support the controlled starting of suitable fixed-speed pumping equipment.
Oil and Gas Processing Plants
Compressors, process pumps and ventilation equipment require reliable motor starting. Controlled acceleration helps reduce sudden mechanical loading on these systems.
Industrial Manufacturing Facilities
Factories often operate multiple motors connected to the same electrical network. Soft starters help manage the starting demand of individual motors, reducing potential disturbances to other production equipment.
Power Generation Stations
Soft starters can be used with auxiliary equipment such as cooling water pumps and ventilation fans, where controlled starting supports reliable plant operations.
District Cooling and Commercial Facilities
Large cooling plants use motors to operate pumps, compressors and ventilation systems. Medium voltage soft starters may be suitable for equipment that requires smooth starting followed by fixed-speed operation.
How Soft Starters Work in a Water Pumping Station
Consider a large pumping station responsible for supplying water to a residential development.
Several pumps operate within the facility to meet changing water demand. When an additional pump is required, starting its motor at full voltage may temporarily increase electrical demand and cause sudden changes in water pressure.
A soft starter helps manage this situation by allowing the motor to accelerate gradually.
Simplified illustration of a soft starter in an industrial pumping system.
The electrical supply provides power, the soft starter manages motor acceleration, and the motor drives the pump. Electrical protection devices and automation systems work alongside this arrangement to support safe and coordinated operation.
Once the motor reaches its required operating conditions, the bypass system enables normal operation.
This approach can help the pumping station manage electricity demand and achieve a smoother increase in water flow.
Medium Voltage Soft Starters Supplied by Dutco Tennant LLC
As a supplier of MV soft starters in the UAE, Dutco Tennant LLC supports industrial and infrastructure projects across the GCC with motor starting solutions suited to different operational requirements.
Its product portfolio includes reduced-voltage soft starting systems for applications involving pumps, compressors, conveyors, industrial fans and other motor-driven equipment.
Consultants, contractors, system integrators and procurement professionals can assess suitable configurations based on motor ratings, electrical network conditions, starting frequency and the requirements of the connected machinery.
Frequently Asked Questions (FAQs)
1. What is the main purpose of a soft starter?
A soft starter allows an electric motor to start gradually rather than receiving full voltage immediately. This helps reduce sudden electrical demand and mechanical stress during motor acceleration.
2. Why are medium voltage soft starters used in industries?
Medium voltage soft starters are used to manage the starting requirements of large industrial motors that could otherwise draw excessive current and cause temporary disturbances within the electrical network.
3. What is the difference between a soft starter and a VFD?
A soft starter manages motor acceleration during starting, while a variable frequency drive (VFD) can also adjust motor speed throughout normal operation.
4. Can soft starters reduce water hammer in pipelines?
Soft starters can help reduce certain pressure fluctuations caused by sudden pump acceleration. However, additional surge protection may be necessary to address water hammer caused by sudden shutdowns or valve operations.
5. Do soft starters reduce electricity consumption?
Soft starters primarily reduce starting current and mechanical stress. They do not necessarily reduce electricity consumption during normal motor operation.
6. Can a soft starter be installed with an existing motor?
Yes, provided the soft starter is compatible with the motor's voltage, current rating, starting torque, connected equipment and existing electrical protection system.
7. What is the purpose of a bypass in a soft starter?
A bypass allows the motor to operate from its normal electrical supply after the starting process is complete, avoiding unnecessary losses associated with the starting components.
8. Who supplies medium voltage soft starters in the UAE?
Dutco Tennant LLC supplies medium voltage soft starting solutions for industrial motors used in water infrastructure, manufacturing, power generation and other industrial applications across the UAE and GCC.
Reliable Industrial Operations Begin with Controlled Motor Starting
The way an industrial motor starts can influence the performance of the entire electrical and mechanical system.
By managing starting current and allowing gradual acceleration, soft starters help address the challenges associated with sudden motor starting. Their suitability depends on the motor's electrical characteristics, the type of connected machinery and the operating conditions of the facility.
With its range of medium voltage soft starting solutions, Dutco Tennant LLC supports industrial and infrastructure projects across the UAE and GCC in addressing application-specific motor starting requirements.